JKM440M-6TL4-V

Jinko JKM440M-6TL4 440W wiring diagram

JKM440M-6TL4-V TR 60M: 440 W, 120-half-cell monofacial panel. Vmp 33.82 V, Voc 40.92 V, Isc 13.69 A; suitable MPPT and cold-voltage margin are required for a 12 V bank.

Nominal voltage
33.8 V
Rated power
440 W
Rated output
13 A
Units

Wiring diagram

How the Jinko 440W is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Jinko JKM440M-6TL4 440W wiring example with 3 components: Jinko 440W, Solar controller, House bank. 4 cable connections. Crossings are not junctions.Jinko 440W + to Solar controller PV +: 1.5 mm² · 20 A fuse, 3 m one way. Jinko 440W − to Solar controller PV −: 1.5 mm², 3 m one way. Solar controller BATT + to House bank +: 16 mm² · 70 A fuse, 3 m one way. Solar controller BATT − to House bank −: 16 mm², 3 m one wayJinko 440W + to Solar controller PV +: 1.5 mm² · 20 A fuse, 3 m one wayJinko 440W − to Solar controller PV −: 1.5 mm², 3 m one waySolar controller BATT + to House bank +: 16 mm² · 70 A fuse, 3 m one waySolar controller BATT − to House bank −: 16 mm², 3 m one wayJinko JKM440M-6TL4 440WJinko 440W++−−Victron MPPT 100/50. Single-panel, 12 V charging example. Check the actual panel's cold-weather open-circuit voltage, short-circuit current and the controller limits before adapting it.Solar controllerPV +PV +PV −PV −BATT +BATT +BATT −BATT −12 V 200 Ah house bankHouse bank++−−1.5 mm² · 20 A fuse1.5 mm²16 mm² · 70 A fuse16 mm²
Jinko JKM440M-6TL4 440W wiring example with 3 components: Jinko 440W, Solar controller, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

33.82 V panel Vmp

Wire
1.5 mm² · 16 AWG
Example fuse
20 A
Design current
13.0 A
Voltage drop
2.7%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 20 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. TR JKM430-450M-6TL4-(V)-A1-PT), checked 2026-10-01. Manufacturer documentation →

Match the TR 60M JKM440M-6TL4-V

Jinko's TR JKM430-450M-6TL4-(V)-A1-PT sheet explicitly includes JKM440M-6TL4-V. It is a 440 W, 120-half-cell monofacial TR 60M panel; the catalog's unsupported Tiger Pro description has been corrected. The manufacturer-authored Portuguese sheet is archived by SecondSol. Its 440 W STC column, page 2, confirms 33.82 V Vmp, 13.01 A Imp, 40.92 V Voc and 13.69 A Isc.

A separate earlier no-suffix sheet differs slightly. Use the matching nameplate and revision when adding modules to an existing string rather than assuming all Jinko 440 W modules are interchangeable.

Check the MPPT input before stringing panels

For a 12 V battery, use an MPPT controller that accepts the panel's higher working voltage. The Voc temperature coefficient is −0.28%/°C; calculate cold-weather voltage for the complete series string. The sheet also gives +0.048%/°C Isc and −0.35%/°C power coefficients.

Series wiring adds voltage; parallel wiring adds current and possible reverse current into a faulted branch. Check the controller's PV short-circuit-current limit as well as its power and voltage ratings. The table lists 1000/1500 V module-system variants; verify the actual module label rather than selecting the higher figure automatically.

Protect and support the output wiring

The maximum series-fuse rating is 25 A. This ceiling is not a universal fuse recommendation or a connector rating. Determine the need and size of string fuses from the actual array, cable and controller design. Crimp's 20 A terminal allowance remains a planning envelope.

The sheet shows output cable lengths of 290 mm positive and 145 mm negative, or customized lengths. Verify the connector fitted to the supplied panel before choosing extensions; the exact reviewed sheet does not establish one universal mating connector. Secure leads against the frame without tension at the junction box, verify polarity, and isolate before making or breaking connections.

Design the support around the frame drawing

This revision lists 1868 × 1134 × 30 mm and 24.2 kg. The engineering drawing identifies frame geometry and mounting-hole spacing. Use that drawing with the matching installation instructions and mounting-system load data; do not infer clamp positions or torque from a different Jinko generation.

Keep drainage and rear ventilation clear, protect the glass during handling, and avoid lifting by cables. The datasheet's wind/snow test claims are module qualification data, not proof that an arbitrary vehicle roof or bracket arrangement meets the same load capability. Obtain the actual installation manual before final structural attachment.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with JKM440M-6TL4-V connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

JKM440M-6TL4-V TR 60M: 440 W, 120-half-cell monofacial panel. Vmp 33.82 V, Voc 40.92 V, Isc 13.69 A; suitable MPPT and cold-voltage margin are required for a 12 V bank.

Nominal voltage
33.8 V
Rated power
440 W
Rated output
13 A
Panel open-circuit voltage
40.9 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

20 A

−

negative · bidi

20 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Jinko 440W.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.