SPR-MAX3-415

SunPower MAXEON 3 415W wiring diagram

415 W Maxeon 3 entry with an incomplete model suffix. Catalog electrical values match SPR-MAX3-415-BLK-R, but the nameplate must confirm identity before selecting protection and mounting hardware.

Nominal voltage
35.3 V
Rated power
415 W
Rated output
11.8 A
Units

Wiring diagram

How the MAXEON 415W is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

SunPower MAXEON 3 415W wiring example with 3 components: MAXEON 415W, Solar controller, House bank. 4 cable connections. Crossings are not junctions.MAXEON 415W + to Solar controller PV +: 1.5 mm² · 15 A fuse, 3 m one way. MAXEON 415W − to Solar controller PV −: 1.5 mm², 3 m one way. Solar controller BATT + to House bank +: 16 mm² · 70 A fuse, 3 m one way. Solar controller BATT − to House bank −: 16 mm², 3 m one wayMAXEON 415W + to Solar controller PV +: 1.5 mm² · 15 A fuse, 3 m one wayMAXEON 415W − to Solar controller PV −: 1.5 mm², 3 m one waySolar controller BATT + to House bank +: 16 mm² · 70 A fuse, 3 m one waySolar controller BATT − to House bank −: 16 mm², 3 m one waySunPower MAXEON 3 415WMAXEON 415W++−−Victron MPPT 100/50. Single-panel, 12 V charging example. Check the actual panel's cold-weather open-circuit voltage, short-circuit current and the controller limits before adapting it.Solar controllerPV +PV +PV −PV −BATT +BATT +BATT −BATT −12 V 200 Ah house bankHouse bank++−−1.5 mm² · 15 A fuse1.5 mm²16 mm² · 70 A fuse16 mm²
SunPower MAXEON 3 415W wiring example with 3 components: MAXEON 415W, Solar controller, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

35.3 V panel Vmp

Wire
1.5 mm² · 16 AWG
Example fuse
15 A
Design current
11.8 A
Voltage drop
2.4%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 15 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Reviewed against manufacturer family documentation (rev. 544753 Rev. J), checked 2026-10-01. Exact variant details still require confirmation. Manufacturer documentation →

Resolve the full model suffix first

The catalog's shortened SPR-MAX3-415 label omits a critical suffix. The electrical values 35.3 V Vmp, 11.75 A Imp and 40.7 V Voc match SPR-MAX3-415-BLK-R in Maxeon's official 544753 revision J installation manual, table 1, page 4. The all-black catalog image is consistent with that family, but does not provide a readable nameplate to confirm the exact suffix.

The different SPR-MAX3-415-R uses 34.5 V Vmp, 12.03 A Imp and 40.6 V Voc. Its current datasheet must not replace this entry's values just because it also says 415 W. This walkthrough remains family-only until the complete label is confirmed.

Use the matching row for the electrical design

For the BLK-R candidate only, table 1 lists 12.64 A Isc, −0.236%/°C Voc coefficient, and 1000 V maximum module-system voltage. Treat these as conditional on confirming that suffix. Calculate the complete string's cold Voc and applicable tolerances before connecting an MPPT controller. For a 12 V battery, the controller must accept the higher panel voltage and provide the appropriate battery profile.

The manual applies a 1.25 factor to marked voltage/current for component selection and distinguishes multiple series-fuse limits by family. Because the exact suffix remains unresolved, no universal series-fuse value is assigned here. Crimp's 15 A terminal envelope is a planning assumption, not the missing module protection rating.

Match connectors and isolate the circuit

Maxeon requires mating connectors to be the same type and manufacturer, even where local rules might permit alternatives. Keep connections clean, dry and fully engaged; do not leave unmated connectors exposed. Cover the modules and stop current flow before breaking electrical connections. See electrical installation, pages 4–5.

Use matching module types within a combined source circuit. Do not mix nameplates without manufacturer approval. Check polarity and array voltage before connecting to the controller and provide the controller's required battery-side protection.

Check the exact mounting configuration

The manual's mounting appendices distinguish module families and clamp arrangements. Confirm the actual frame and full model before choosing rail positions, clamp zones, grounding hardware or torque. Avoid placing rails under junction boxes, attaching items to the backsheet, or leaving sharp objects where the panel can flex against them.

Preserve drainage, ventilation and connector access. The image and broad 415 W label are insufficient to establish the mechanical design. Follow the mounting section and relevant appendix once identity is confirmed.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with SPR-MAX3-415 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

415 W Maxeon 3 entry with an incomplete model suffix. Catalog electrical values match SPR-MAX3-415-BLK-R, but the nameplate must confirm identity before selecting protection and mounting hardware.

Nominal voltage
35.3 V
Rated power
415 W
Rated output
11.8 A
Panel open-circuit voltage
40.7 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

15 A

−

negative · bidi

15 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works