Victron BatteryProtect 100 wiring diagram
Programmable 12/24 V disconnect, 100 A continuous up to 40 °C, with a 6–35 V operating range. Current must flow IN to OUT: battery to loads, or charger to battery in a separate charge-disconnect circuit. Control inverters through their remote input; do not route their main DC feed through this unit.
Wiring diagram
How the BP-100 is wired.
Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.
Cable sizing for this example
Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.
Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. 05 - 02/2025), checked 2026-09-29. Manufacturer documentation →
Which BatteryProtect is this?
This is the BatteryProtect 12/24V-100A, programmed with its PROG and GND pins. Use the BP-100 specification column in the manual. The similarly named Smart BatteryProtect has different programming options; the filename of Victron's PDF includes "Smart", but its cover and instructions identify the non-Smart BatteryProtect.
The BP-100 carries 100 A continuously at ambient temperatures up to 40 °C. The manual derates operation at 50 °C to 60% of nominal load. It lists 600 A peak without specifying a duration, so that figure does not establish an inverter-starting allowance. The operating range is 6-35 V; its M8 connections use 9 N·m torque.
How do IN and OUT connect?
For load protection, connect battery positive through a suitable fuse to IN, and connect OUT to the protected DC loads. Current may flow only from IN to OUT. For a separate charger-disconnect installation, the charger positive instead goes to IN and the battery to OUT. One unit cannot serve both directions, and reverse current damages it.
Crimp shows the two main studs. The real unit also needs its separate GND connection: the supplied 1.5 mm² wire goes directly to battery negative or vehicle chassis, serves no other equipment, and needs protection; Victron specifies that a 300 mA fuse is sufficient. Remote, alarm and programming connections are not shown on the canvas. See manual sections 3.1-3.3 for these circuits.
Mount with ventilation, preferably within 50 cm of the battery and away from gases above it. The main battery fuse must suit the cable and installation; the manual does not prescribe a universal BP-100 fuse size.
What must be configured before connecting loads?
Leave OUT disconnected until programming is complete. The unit remembers its initial 12 V or 24 V detection; setting d repeats detection when moving it to another system. The factory thresholds are 10.5 V disconnect and 12 V reconnect for a 12 V bank, doubled for 24 V. Choose thresholds for the battery rather than assuming those defaults suit it.
Mode C requires an external BMS control signal. In that mode the unit's own undervoltage thresholds and alarm are disabled. A drop-in lithium battery without a load/charge-disconnect signal uses mode A or B instead.
Do not put an inverter or inverter/charger's main DC feed through the BatteryProtect. Victron requires control through the inverter's remote on/off port instead; see manual section 3.2.
Fit check
Connect it to the rest of your system.
Describe your setup to draft a system with BatteryProtect 100 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.
The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.
Enable JavaScript to describe your system.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
Programmable 12/24 V disconnect, 100 A continuous up to 40 °C, with a 6–35 V operating range. Current must flow IN to OUT: battery to loads, or charger to battery in a separate charge-disconnect circuit. Control inverters through their remote input; do not route their main DC feed through this unit.
Connection limits are listed in the terminal map. Use the manufacturer's documentation for the full specifications.
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
IN
neutral · input
OUT
neutral · output
GND
signal · input
A dash means a current rating is not specified here.
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.
Read how the sizing worksNext step
Plan your installation with BP-100.
Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.
Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.