Distribution

Victron Argofet 100-2 connections

Review the Victron Argofet 100-2 connections, setup and installation requirements. This overview does not calculate cable or protection sizes.

Units

Connection overview

Argofet 100-2 connections.

See how this component fits into a system. Use the manufacturer’s installation instructions for the complete connections.

Victron Argofet 100-2 connection overview with 4 components: Argofet 100-2, Matched 12 V alternator, 12 V starter battery, 12 V house battery. 5 cable connections. Crossings are not junctions.Matched 12 V alternator + to Argofet 100-2 ALT. Argofet 100-2 OUT 1 to 12 V starter battery +. Matched 12 V alternator − to 12 V starter battery −. Argofet 100-2 OUT 2 to 12 V house battery +. Matched 12 V alternator − to 12 V house battery −Matched 12 V alternator + to Argofet 100-2 ALTArgofet 100-2 OUT 1 to 12 V starter battery +Matched 12 V alternator − to 12 V starter battery −Argofet 100-2 OUT 2 to 12 V house battery +Matched 12 V alternator − to 12 V house battery −Victron Argofet 100-2. The alternator feeds separate battery banks through the numbered outputs, with common battery negatives. The required Ground blade and optional Energize input are absent from the symbol; follow the complete manufacturer diagram before connecting it. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.Argofet 100-2ALTALTOUT 1OUT 2Matched 12 V alternator. Alternator rating, field type, battery protection and harness must be selected together. No alternator current rating or generic fuse has been assumed.Matched 12 V alternator++−−12 V starter battery. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.12 V starter battery++−−12 V house battery. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.12 V house battery++−−
Victron Argofet 100-2 connection overview with 4 components: Argofet 100-2, Matched 12 V alternator, 12 V starter battery, 12 V house battery. 5 cable connections. Crossings are not junctions.The alternator feeds separate battery banks through the numbered outputs, with common battery negatives. The required Ground blade and optional Energize input are absent from the symbol; follow the complete manufacturer diagram before connecting it. Connection overview only. Cable lengths are placeholders; use the complete manufacturer diagram to select conductors and protection. No automatic fuse or cable-size recommendation is supplied by this example.
Edit this connection overview

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 14 - 2021-10-13), checked 2026-10-01. Manufacturer documentation →

What does the Argofet 100-2 do?

The 100-2 distributes one alternator or charger output to 2 battery banks while blocking current from one bank back into another. The manufacturer datasheet specifies 100 A maximum charging current and 100 A maximum alternator current for the complete unit. It is not 100 A independently available from each output.

It automatically operates on 12 V or 24 V systems. The published drop is below 0.02 V at low current and about 0.1 V at higher current. Cable losses still matter. This device does not set a battery charging profile, limit alternator current or replace a lithium battery's BMS.

How are the main terminals connected?

Connect the source positive to INPUT/ALT and each battery positive to its own numbered output. The model uses M8 main studs. Connect the battery negatives to a common negative bus. Protect the battery-fed conductors and source circuit according to their actual cables and fault sources; the isolator is not a fuse.

The separate Ground blade terminal is required, using at least 2.5 mm² to the common negative bus. The canvas symbol shows only the high-current positive terminals, so the page leaves the part unwired and does not publish a cable/fuse reference. Add the complete arrangement from the installation diagram on page 1 of the manual, including this ground.

When is Energize used?

Some alternators need battery voltage at B+ before they begin charging. The Argofet blocks reverse battery current, so the optional current-limited Energize input can supply that initial voltage when the engine run/stop switch is closed. The manual specifies a minimum 2.5 mm² lead for this connection. Determine whether the installed alternator needs it; it is not a field-control output or a substitute for regulator wiring.

What should be checked after installation?

Mount the heatsink on a nonflammable surface and leave it able to shed heat. Verify polarity and bank separation before starting the engine, then confirm that each bank receives the expected charging voltage. The blue LED indicates voltage at the input; it does not prove every output cable, fuse or battery connection is sound. Check alternator regulation, battery chemistry compatibility and BMS shutdown behaviour separately before relying on a mixed-bank installation.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Argofet 100-2 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

FET-based battery isolator: one alternator input, two isolated outputs to charge two banks independently. 100 A maximum total charging/alternator current, shared by the outputs. Drop below 0.02 V at low current, about 0.1 V at higher current. Requires a separate common-negative connection.

Use the manufacturer's complete diagram to select conductors, protection and control wiring.

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

ALT

positive · input

100 A

OUT 1

positive · output

100 A

OUT 2

positive · output

100 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Connection overview. This diagram explains the connection arrangement; it does not calculate cable sizes or protection for the installation. Follow the manufacturer’s complete wiring and protection instructions.

Read how the sizing works

Next step

Plan your installation with Argofet 100-2.

Open the connection overview as a new project, or add this component to a diagram you already have.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.