NPA100S-12I

Newpowa 100W Mono wiring diagram

100W rigid mono panel with 9-busbar cells, 12V nominal (Vmp 19.2V) — works with PWM or MPPT controllers. MC4 leads.

Nominal voltage
19.2 V
Rated power
100 W
Rated output
5.2 A
Units

Wiring diagram

How the 100W Mono is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Newpowa 100W Mono wiring example with 3 components: 100W Mono, Solar controller, House bank. 4 cable connections. Crossings are not junctions.100W Mono + to Solar controller PV +: 1.5 mm² · 7.5 A fuse, 3 m one way. 100W Mono − to Solar controller PV −: 1.5 mm², 3 m one way. Solar controller BATT + to House bank +: 4 mm² · 15 A fuse, 3 m one way. Solar controller BATT − to House bank −: 4 mm², 3 m one way100W Mono + to Solar controller PV +: 1.5 mm² · 7.5 A fuse, 3 m one way100W Mono − to Solar controller PV −: 1.5 mm², 3 m one waySolar controller BATT + to House bank +: 4 mm² · 15 A fuse, 3 m one waySolar controller BATT − to House bank −: 4 mm², 3 m one wayNewpowa 100W Mono100W Mono++−−Victron MPPT 75/10. Single-panel, 12 V charging example. Check the actual panel's cold-weather open-circuit voltage, short-circuit current and the controller limits before adapting it.Solar controllerPV +PV +PV −PV −BATT +BATT +BATT −BATT −12 V 200 Ah house bankHouse bank++−−1.5 mm² · 7.5 A fuse1.5 mm²4 mm² · 15 A fuse4 mm²
Newpowa 100W Mono wiring example with 3 components: 100W Mono, Solar controller, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

19.23 V panel Vmp

Wire
1.5 mm² · 16 AWG
Example fuse
7.5 A
Design current
5.2 A
Voltage drop
1.9%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 7.5 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Undated manufacturer datasheet; accessed 2026-10-01), checked 2026-10-01. Manufacturer documentation →

Identify NPA100S-12I and the source edition

The exact NPA100S-12I manufacturer sheet describes a 100 W, 33-cell, 9-busbar monocrystalline panel. It was recovered from the public Solar Panels archive linked by Newpowa's official download page. The document prints no revision date; its PDF metadata dates creation to September 2022, which is not treated as a printed issue identifier.

The electrical table, PDF page 2, confirms 19.23 V Vmp, 5.21 A Imp, 22.12 V Voc and 5.50 A Isc. Those values match the existing catalog operating point. Current Newpowa 100 W products with different suffixes must be checked separately.

Connect the panel through a charge controller

Route the marked positive and negative leads to a compatible solar controller, then connect the controller's protected battery output using its own instructions. A nominal 12 V description does not mean this panel can be connected directly to a battery. Verify controller startup voltage, maximum PV voltage and current, and select the charging profile for the actual battery chemistry.

The rear drawing labels 2.5 mm² output cables, 900 mm long. Match extension connectors to the actual fitted type and manufacturer; the drawing does not establish a universal mating connector certification. Secure the leads without tension at the junction box and protect extensions from roof-edge abrasion.

Calculate cold voltage using the correct units

The sheet gives a Voc temperature coefficient of −(80 ± 10) mV/°C per module. This is an absolute voltage change, not a percentage coefficient. For example, the central coefficient increases a single panel's Voc by 2.0 V when cell temperature falls from 25°C to 0°C, before tolerances and other required margins. Use the design minimum temperature and full coefficient tolerance for actual string sizing.

Series wiring adds module voltages; parallel wiring adds currents. The reviewed sheet does not specify maximum series-fuse or maximum system-voltage ratings. Obtain those from the actual label or Newpowa before building a multi-string array. Crimp's 12 A terminal allowance is a planning value, not either missing rating.

Match the frame and mounting points

The panel measures 980 × 530 × 30 mm and weighs 6.03 kg. Its rear drawing distinguishes four mounting slots from two 5 mm grounding holes. Use mounting hardware designed for this frame and the supporting structure; do not confuse the grounding holes with structural attachment points.

Confirm clamp/bolt torque and grounding hardware from the supplied installation instructions, as this datasheet does not specify them. Preserve drainage and ventilation, cover and isolate the module during assembly, and never separate PV connectors under load. Inspect cable support and attachment after commissioning.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with NPA100S-12I connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

100W rigid mono panel with 9-busbar cells, 12V nominal (Vmp 19.2V) — works with PWM or MPPT controllers. MC4 leads.

Nominal voltage
19.2 V
Rated power
100 W
Rated output
5.2 A
Panel open-circuit voltage
22.1 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

12 A

−

negative · bidi

12 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with 100W Mono.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.