Yuma 200 (CIGS)

BougeRV 200W Flexible wiring diagram

Yuma 200 CIGS flexible panel, 1.5 mm thick, with adhesive and drilled mounting variants. Vmp 24 V, Voc 30.4 V and Isc 9.48 A; verify cold voltage and the actual mounting version.

Nominal voltage
24 V
Rated power
200 W
Rated output
8.5 A
Units

Wiring diagram

How the 200W Flex is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

BougeRV 200W Flexible wiring example with 3 components: 200W Flex, Solar controller, House bank. 4 cable connections. Crossings are not junctions.200W Flex + to Solar controller PV +: 1.5 mm² · 15 A fuse, 3 m one way. 200W Flex − to Solar controller PV −: 1.5 mm², 3 m one way. Solar controller BATT + to House bank +: 10 mm² · 25 A fuse, 3 m one way. Solar controller BATT − to House bank −: 10 mm², 3 m one way200W Flex + to Solar controller PV +: 1.5 mm² · 15 A fuse, 3 m one way200W Flex − to Solar controller PV −: 1.5 mm², 3 m one waySolar controller BATT + to House bank +: 10 mm² · 25 A fuse, 3 m one waySolar controller BATT − to House bank −: 10 mm², 3 m one wayBougeRV 200W Flexible200W Flex++−−Victron MPPT 100/20. Single-panel, 12 V charging example. Check the actual panel's cold-weather open-circuit voltage, short-circuit current and the controller limits before adapting it.Solar controllerPV +PV +PV −PV −BATT +BATT +BATT −BATT −12 V 200 Ah house bankHouse bank++−−1.5 mm² · 15 A fuse1.5 mm²10 mm² · 25 A fuse10 mm²
BougeRV 200W Flexible wiring example with 3 components: 200W Flex, Solar controller, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

24 V panel Vmp

Wire
1.5 mm² · 16 AWG
Example fuse
15 A
Design current
8.5 A
Voltage drop
2.5%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 15 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Undated manufacturer manual; accessed 2026-10-01), checked 2026-10-01. Manufacturer documentation →

Identify Yuma 200 and the mounting version

The Yuma 200 CIGS manual has separate adhesive and drilled variants. Both share 200 W, 24 V Vmp, 8.52 A Imp, 30.4 V Voc and 9.48 A Isc, each electrical figure shown with ±5% tolerance. This matches the catalog electrical values. The older generic CIGS manual has different ratings and is not used for this Yuma row. See electrical table, printed page 12.

Both variants are 1.5 mm thick, correcting the earlier 2.5 mm description. Adhesive Yuma 200 is 2087.5 × 660 mm, 3.83 kg; drilled Yuma 200 is 2102.5 × 689 mm, 2.7 kg. Confirm which mounting version was supplied before laying out the roof.

Connect through a compatible solar input

The system diagrams, printed pages 9–10, show a charge controller between the module and battery, or a compatible power station solar input. For a 12 V house battery, an MPPT controller can use the panel's higher working voltage; confirm its PV voltage/current limits before wiring.

Series connection adds module voltage; parallel connection adds current. Verify polarity from the actual marked leads and use compatible connectors and protected extensions. A plug adapter changes the connector interface, not the receiving device's electrical limits. Isolate the load before separating connectors.

Check cold voltage and missing fuse data

The exact Yuma table gives −0.28%/°C Voc temperature coefficient and 1000 V maximum module-system voltage. Apply cold-temperature correction and the stated voltage tolerance to the complete series string before comparing it with the controller's limit.

The reviewed Yuma manual does not publish a maximum series-fuse rating. Do not import the old generic CIGS panel's fuse value or read Crimp's 15 A terminal allowance as that missing specification. Obtain the actual label/manufacturer limit before arranging parallel strings and selecting reverse-current protection.

Support the laminate and preserve output

Use the supplied mounting method for the adhesive or drilled version. The adhesive instruction describes removing the backing film before attachment; it does not validate every roof coating, adhesive substrate or vehicle installation. Confirm surface preparation and attachment requirements before permanent bonding.

The manual says to roll with the solar face outward; rolling inward can damage the panel. Avoid sharp creases, unsupported cable strain and walking loads. Keep the surface clear of dirt and persistent shadows. The troubleshooting pages 14–15 explain why heat, shading, orientation and the connected controller can reduce measured output below the 200 W laboratory rating.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Yuma 200 (CIGS) connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Yuma 200 CIGS flexible panel, 1.5 mm thick, with adhesive and drilled mounting variants. Vmp 24 V, Voc 30.4 V and Isc 9.48 A; verify cold voltage and the actual mounting version.

Nominal voltage
24 V
Rated power
200 W
Rated output
8.5 A
Panel open-circuit voltage
30.4 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · bidi

15 A

−

negative · bidi

15 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with 200W Flex.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.