Victron Blue Smart IP67 24/5 wiring diagram

Blue Smart IP67 24/5: 5A charger for 24V batteries, with 2A Low mode and M8 ring leads. Protective earth is required. Separate 230V (180–265 VAC) and 120V (100–130 VAC) versions; mount protected and ventilated.

Compatible systems
24 V
Rated output
5 A
Units

Wiring diagram

How the BS IP67 24/5 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron Blue Smart IP67 24/5 wiring example with 3 components: BS IP67 24/5, Battery disconnect, House bank. 3 cable connections. Crossings are not junctions.BS IP67 24/5 BATT + to Battery disconnect A: 1.5 mm² · 7.5 A fuse, 3 m one way. BS IP67 24/5 BATT − to House bank −: 1.5 mm², 3 m one way. Battery disconnect B to House bank +: 1.5 mm² · 7.5 A fuse, 30 cm one wayBS IP67 24/5 BATT + to Battery disconnect A: 1.5 mm² · 7.5 A fuse, 3 m one wayBS IP67 24/5 BATT − to House bank −: 1.5 mm², 3 m one wayBattery disconnect B to House bank +: 1.5 mm² · 7.5 A fuse, 30 cm one wayVictron Blue Smart IP67 24/5BS IP67 24/5BATT +BATT +BATT −BATT −Main Battery SwitchBattery disconnectAB24 V 50 Ah AGM placeholder bank. Example bank only: select the correct charger profile and confirm the actual battery's capacity, charging-current acceptance, voltage and temperature limits. Placeholder current limits are not manufacturer battery specifications.House bank++−−1.5 mm² · 7.5 A fuse1.5 mm²1.5 mm² · 7.5 A fuse
Victron Blue Smart IP67 24/5 wiring example with 3 components: BS IP67 24/5, Battery disconnect, House bank. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

24 V system

Wire
1.5 mm² · 16 AWG
Example fuse
7.5 A
Design current
5 A
Voltage drop
1.5%

Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 7.5 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Rev 06 — 09/2026), checked 2026-10-01. Manufacturer documentation →

Which 24/5 charger is this?

The Blue Smart IP67 24/5 is a mains charger for a nominal 24 V battery, with 5 A maximum charge current and 2 A Low mode. It is not an inverter or a DC-DC converter. Confirm the AC nameplate: the reviewed 230 V version accepts 180–265 VAC; the separate 120 V manual specifies 100–130 VAC. These are separate products, not one universal-input unit.

How do the connections map?

BATT + / BATT − represent the permanently attached red/black cable with M8 ring terminals. This model is supplied with 4 mm² cable. The manual permits shortening and reterminating the DC lead; an extension needs a separate conductor, voltage-drop, and protection check.

AC L / AC N / AC ⏚ represent the mains cord, including its protective-earth conductor. Preserve that earth connection through the genuine supply cord and an earthed outlet; the revised symbol includes it. Connect DC with sources and loads isolated, verify polarity, then apply AC. For temporary charging in a vehicle, follow the manual's chassis-connection sequence.

Which protection is required?

The external-protection table, printed page 16 gives 7.5–40 A for this model, selected with the actual conductor and fuse type. Place that protection close to battery positive. This model also has a 20 A fuse in the supplied DC cable near the charger. It cannot protect the cable between itself and the battery.

What must be configured?

Use VictronConnect to choose chemistry and current. Normal mode uses 28.8 / 27.6 / 26.4 V for absorption, float, and storage. The lithium preset uses 28.4 V absorption and disables lead-acid temperature compensation. Those presets require the battery manufacturer's approval; they do not bypass a BMS or permit charging lithium below 0°C. Select Low mode if the bank cannot accept 5 A. House loads consume part of the charger output, reducing current available to recharge the battery.

Where should it be mounted?

Mount vertically with both cables downward, on a nonflammable surface, with 100 mm clearance above and below. Despite the IP67 enclosure, the installation chapter calls for a protected, ventilated location away from flammable gases and liquids, never directly above or sealed in with the battery. Rated output is available up to 40°C, then derates. Waterproofing does not remove the need to protect plugs and cable joints.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Blue Smart IP67 24/5 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Blue Smart IP67 24/5: 5A charger for 24V batteries, with 2A Low mode and M8 ring leads. Protective earth is required. Separate 230V (180–265 VAC) and 120V (100–130 VAC) versions; mount protected and ventilated.

Compatible systems
24 V
Rated output
5 A
Planning charge current
5 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

AC L

neutral · input

3 A

AC N

neutral · input

3 A

AC ⏚

ground · bidi

3 A

BATT +

positive · output

5 A

BATT −

negative · output

5 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with BS IP67 24/5.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.