SmartSolar 75/10

Victron MPPT 75/10 wiring diagram

Bluetooth MPPT charger for 12/24 V batteries, with 10 A charge output, 75 V maximum PV open-circuit voltage and nominal PV power of 145 W at 12 V or 290 W at 24 V. The physical 15 A LOAD output is not shown in this symbol.

Compatible systems
12 V / 24 V
Rated output
10 A
PV open-circuit limit
75 V
Units

Wiring diagram

How the MPPT 75/10 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron MPPT 75/10 wiring example with 3 components: Reference PV, MPPT 75/10, House bank. 4 cable connections. Crossings are not junctions.Reference PV PV + to MPPT 75/10 PV +: 1.5 mm² · 7.5 A fuse, 3 m one way. MPPT 75/10 BATT + to House bank +: 4 mm² · 15 A fuse, 3 m one way. Reference PV PV − to MPPT 75/10 PV −: 1.5 mm², 3 m one way. MPPT 75/10 BATT − to House bank −: 4 mm², 3 m one wayReference PV PV + to MPPT 75/10 PV +: 1.5 mm² · 7.5 A fuse, 3 m one wayMPPT 75/10 BATT + to House bank +: 4 mm² · 15 A fuse, 3 m one wayReference PV PV − to MPPT 75/10 PV −: 1.5 mm², 3 m one wayMPPT 75/10 BATT − to House bank −: 4 mm², 3 m one way120 W reference PV arrayReference PVPV +PV +PV −PV −Victron MPPT 75/10MPPT 75/10PV +PV +PV −PV −BATT +BATT +BATT −BATT −12 V 200 Ah house bankHouse bank++−−1.5 mm² · 7.5 A fuse4 mm² · 15 A fuse1.5 mm²4 mm²
Victron MPPT 75/10 wiring example with 3 components: Reference PV, MPPT 75/10, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
4 mm² · 11 AWG
Example fuse
15 A
Design current
10 A
Voltage drop
2.2%

Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 4 mm² (11 AWG) marine cable
  2. Terminations for 4 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 15 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 10 - 02/2026), checked 2026-09-29. Manufacturer documentation →

What does SmartSolar 75/10 mean?

This is the Bluetooth SmartSolar MPPT 75/10, for 12 V or 24 V batteries. Its name gives the 75 V maximum PV open-circuit voltage and 10 A maximum battery charge current. Nominal array power is 145 W at 12 V or 290 W at 24 V. Extra panel power can be clipped; it does not relax the voltage or current limits. The manual's specifications, section 9.1 distinguish these ratings.

How is the 75/10 connected?

Connect the battery to BATT + / BATT − first, wait 10 seconds and verify the detected voltage in VictronConnect. Connect DC loads, then the panel array to PV + / PV −, following section 4.6. The real controller also has a 15 A LOAD output, which this catalog symbol omits. Loads drawn directly on the battery bus do not receive its BatteryLife or low-voltage-disconnect control.

Section 4.2 requires 15–20 A battery-side fuse protection, even with the controller's own fuse. Terminals accept up to 6 mm² / 10 AWG and tighten to 0.75 Nm. Size the battery cable for its actual routing and length. Mount vertically with terminals down, 100 mm ventilation space above and below, within 3 m of the battery and never directly above it.

Which solar-array limits need checking?

PV voltage must exceed battery voltage by 5 V to start; once running, the minimum difference is 1 V. Check cold-weather array Voc against the 75 V ceiling using the panel temperature coefficient.

Victron's sources disagree on maximum PV short-circuit current: manual revision 10 lists 10 A, while the published datasheet lists 13 A. The catalog retains the datasheet's 13 A PV-terminal value. Do not treat that as approval for an array above the manual's 10 A figure; confirm the applicable limit with Victron for the unit being installed.

What remains to be set up?

Choose battery chemistry and charging voltages in VictronConnect before use. Bluetooth and VE.Direct provide monitoring; neither appears as a power terminal in Crimp. Charge profiles, the physical LOAD output and cold-weather Voc are not verified by the simple charging example.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with SmartSolar 75/10 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Bluetooth MPPT charger for 12/24 V batteries, with 10 A charge output, 75 V maximum PV open-circuit voltage and nominal PV power of 145 W at 12 V or 290 W at 24 V. The physical 15 A LOAD output is not shown in this symbol.

Compatible systems
12 V / 24 V
Rated output
10 A
Planning charge current
10 A
PV open-circuit limit
75 V

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

PV +

positive · input

13 A

PV −

negative · input

13 A

BATT +

positive · output

10 A

BATT −

negative · output

10 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with MPPT 75/10.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.