Monitoring

Victron GlobalLink 520 wiring diagram

Cellular (LTE-M) VRM uplink for small Victron systems without a GX device. Logs MPPTs and shunts to VRM directly over a built-in 4G modem. Free 5-year SIM included.

Continuous draw
0.1 A
Units

Wiring diagram

How the GlobalLink 520 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron GlobalLink 520 wiring example with 3 components: House bank, Fused DC distribution, GlobalLink 520. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to GlobalLink 520 V+ (8–70V): 1.5 mm² · 1 A fuse, 3 m one way. Fused DC distribution 1 to GlobalLink 520 GND: 1.5 mm², 3 m one way. House bank + to Fused DC distribution IN +: 1.5 mm² · 1 A fuse, 30 cm one way. House bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one wayFused DC distribution 1 to GlobalLink 520 V+ (8–70V): 1.5 mm² · 1 A fuse, 3 m one wayFused DC distribution 1 to GlobalLink 520 GND: 1.5 mm², 3 m one wayHouse bank + to Fused DC distribution IN +: 1.5 mm² · 1 A fuse, 30 cm one wayHouse bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Victron GlobalLink 520GlobalLink 520V+ (8–70V)V+ (8–70V)GNDGND1.5 mm² · 1 A fuse1.5 mm²1.5 mm² · 1 A fuse1.5 mm²
Victron GlobalLink 520 wiring example with 3 components: House bank, Fused DC distribution, GlobalLink 520. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
1.5 mm² · 16 AWG
Example fuse
1 A
Design current
0.1 A
Voltage drop
0.0%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 1 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 19 - 08/2026), checked 2026-10-01. Manufacturer documentation →

What does GlobalLink 520 do?

GlobalLink 520 sends compatible Victron device measurements to VRM over LTE-M. It is distinct from the newer GlobalLink 530's cellular modem. Check current LTE-M coverage for the installation location; ordinary phone coverage does not prove LTE-M service. The included prepaid connectivity lasts five years under Victron's service terms, not indefinitely.

How is it powered and connected?

Use the supplied 1.5 m power cable with 1 A inline fuse and M10 eyelets on an 8–70 V DC supply. The two VE.Direct ports can connect two supported devices; the cables are separate accessories. Compatible Smart devices can also report through Bluetooth Instant Readout after setup. The canvas represents only the DC feed, not the data, digital-input or relay wiring.

The current datasheet gives 50 mA at 12 V with Bluetooth enabled and the relay open, rising to 64 mA with the relay closed. Bluetooth-disabled and higher-voltage figures differ. The 1 A fuse must not be mistaken for continuous consumption.

How is it commissioned?

Record the VRM Portal ID from the unit, connect the supported devices, power it and follow the LED sequence in manual §3. Register the installation in VRM and verify fresh measurements from each intended source. Configure wireless devices in VictronConnect and check that their Instant Readout support is enabled. Allow for the documented reporting interval before deciding that a value is missing.

Can it act as a fast alarm or remote switch?

Updates normally occur every 15 minutes. Digital-input notifications and queued relay commands can therefore be delayed by that interval or longer if connectivity is lost. This is unsuitable as an immediate protective trip or emergency shutdown path. The relay is a limited control contact, not a battery-current switch; use the manual's contact rating for any external circuit. GlobalLink monitoring does not replace a GX controller where the system requires GX coordination or local control.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with GlobalLink 520 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Cellular (LTE-M) VRM uplink for small Victron systems without a GX device. Logs MPPTs and shunts to VRM directly over a built-in 4G modem. Free 5-year SIM included.

Continuous draw
0.1 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

V+ (8–70V)

positive · input

1 A

GND

ground · input

1 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with GlobalLink 520.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.