Starlink Mini with integrated router: 12–48 V DC, 60 W input rating and 25–40 W average consumption. USB-C operation requires the specified 100 W, 20 V / 5 A PD source and accessory cable; 60 W is not a verified startup-surge rating.

Nominal voltage
12 V
Compatible systems
12 V / 24 V / 48 V
Rated power
30 W
Units

Wiring diagram

How the Starlink Mini is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Starlink Mini wiring example with 3 components: House bank, Fused DC distribution, Starlink Mini. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to Starlink Mini +: 1.5 mm² · 5 A fuse, 3 m one way. Fused DC distribution 1 to Starlink Mini −: 1.5 mm², 3 m one way. House bank + to Fused DC distribution IN +: 1.5 mm² · 5 A fuse, 30 cm one way. House bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one wayFused DC distribution 1 to Starlink Mini +: 1.5 mm² · 5 A fuse, 3 m one wayFused DC distribution 1 to Starlink Mini −: 1.5 mm², 3 m one wayHouse bank + to Fused DC distribution IN +: 1.5 mm² · 5 A fuse, 30 cm one wayHouse bank − to Fused DC distribution IN −: 1.5 mm², 30 cm one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Starlink MiniStarlink Mini++−−1.5 mm² · 5 A fuse1.5 mm²1.5 mm² · 5 A fuse1.5 mm²
Starlink Mini wiring example with 3 components: House bank, Fused DC distribution, Starlink Mini. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
1.5 mm² · 16 AWG
Example fuse
5 A
Design current
2.5 A
Voltage drop
1.5%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 1.5 mm² (16 AWG) marine cable
  2. Terminations for 1.5 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 5 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Undated manufacturer document; printed revision not established), checked 2026-10-01. Manufacturer documentation →

Mini input and energy use

This is Starlink Mini with the router integrated into the antenna, not a Standard terminal or a separate Mini Router. The official specification sheet gives a 12–48 V, 60 W input rating and 25–40 W average consumption. The 60 W figure is an input rating, not a documented startup surge duration. The catalog’s single average-current estimate should be checked against real usage.

Supply connection

`+` and `−` represent the Mini’s DC input via the correct cable and barrel connector. They are not bare binding posts or Ethernet power pins. Fully seat the power plug so its face is flush with the terminal. Design the source and cable so voltage at the Mini remains inside its input range under load; a nominal 12 V battery and a long cable can fall below 12 V at the device.

USB-C and outdoor sealing

The official specification requires a 100 W, 20 V/5 A minimum USB-PD source when using Starlink’s USB-C-to-barrel accessory. A charger labeled only 60 W is not equivalent to that requirement. The Mini’s IP67 Type 4 rating depends on the correct power cable and Ethernet plug/cable being installed. The setup guide explicitly says a standard RJ45 cable removes the IP67 rating.

Setup and drawing limits

Use the app’s obstruction check for the required clear sky view, connect to the STARLINK Wi-Fi network and follow the alignment prompt. Check app alerts and the rear status light before assuming a power fault. The drawing omits the network connection, cable accessory, mounting and any DC converter. It cannot verify service availability, in-motion service permissions or endurance from a changing network load.

Source: manufacturer document — setup PDF pp. 3–6; electrical/environmental values in the official Mini specification sheet, PDF p. 3.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Starlink Mini connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Starlink Mini with integrated router: 12–48 V DC, 60 W input rating and 25–40 W average consumption. USB-C operation requires the specified 100 W, 20 V / 5 A PD source and accessory cable; 60 W is not a verified startup-surge rating.

Nominal voltage
12 V
Compatible systems
12 V / 24 V / 48 V
Rated power
30 W
Continuous draw
2.5 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

6 A

−

negative · input

6 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Starlink Mini.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.