Charger

Victron Orion-Tr Smart 12/12-30 wiring diagram

Isolated 30A DC-DC charger from start to house battery. Engine-run detection from input voltage; Victron's manual calls for a 60A fuse on the input side.

Compatible systems
12 V
Rated output
30 A
Units

Wiring diagram

How the Orion 30A is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron Orion-Tr Smart 12/12-30 wiring example with 3 components: Starter bank, Orion 30A, House bank. 4 cable connections. Crossings are not junctions.Starter bank + to Orion 30A IN +: 16 mm² · 50 A fuse, 3 m one way. Orion 30A OUT + to House bank +: 10 mm² · 40 A fuse, 3 m one way. Starter bank − to Orion 30A IN −: 16 mm², 3 m one way. Orion 30A OUT − to House bank −: 10 mm², 3 m one wayStarter bank + to Orion 30A IN +: 16 mm² · 50 A fuse, 3 m one wayOrion 30A OUT + to House bank +: 10 mm² · 40 A fuse, 3 m one wayStarter bank − to Orion 30A IN −: 16 mm², 3 m one wayOrion 30A OUT − to House bank −: 10 mm², 3 m one way12 V 200 Ah starter bankStarter bank++−−Victron Orion-Tr Smart 12/12-30Orion 30AIN +IN +IN −IN −OUT +OUT +OUT −OUT −12 V 200 Ah house bankHouse bank++−−16 mm² · 50 A fuse10 mm² · 40 A fuse16 mm²10 mm²
Victron Orion-Tr Smart 12/12-30 wiring example with 3 components: Starter bank, Orion 30A, House bank. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
10 mm² · 8 AWG
Example fuse
40 A
Design current
30 A
Voltage drop
2.7%

Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 10 mm² (8 AWG) marine cable
  2. Terminations for 10 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 40 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 14 — 02/2026), checked 2026-09-11. Manufacturer documentation →

Which Orion-Tr Smart 12/12-30 is this?

This is the isolated Orion-Tr Smart 12/12-30A (360 W), Victron part ORI121236120, the model most "Orion TR Smart 30A wiring diagram" searches mean. Victron also sells a non-isolated 12/12-30 that shares one negative between input and output; this page models the isolated one, whose input and output returns are separate. The product family page rates it at 30 A continuous at 40 °C, a 40 A peak for 10 seconds, about 87 % efficiency and a 10–17 V input.

How is the Orion-Tr Smart 12/12-30 wired?

IN + comes from the starter battery through a fuse at that battery; OUT + charges the house or leisure battery through a fuse at the house battery. IN − and OUT − are two separate returns on this isolated model, one to each bank. Victron's manual calls for a 60 A fuse on the input side, and the installation section carries the full cable-and-fuse table by run length; the screw terminals accept up to 16 mm² (6 AWG). Those fuses protect the cable, and belong at the battery end of each run.

The technical reference above sizes the example run with Crimp's engine from the catalog's terminal ratings, and the starter lets you change the lengths. The manual's table is the floor.

What should I bear in mind with the Orion-Tr Smart 12/12-30?

  • Heat is the defining constraint of this model. At 87 % efficiency roughly an eighth of the throughput becomes heat, and the datasheet rates the 30 A only up to 40 °C, derating about 3 % per degree above it. A closed locker or an engine bay in summer means less than 30 A. Mount it fins-vertical with air moving past; IP43 only applies with the terminals pointing down.
  • Engine detection reads the input voltage. Smart alternators on Euro 5 and Euro 6 vehicles drop the starter side below the detection threshold once that battery is full, and the charger stops. The manual's engine shutdown detection section describes the override from an ignition-switched or D+ feed on the remote connector. Turning detection off in VictronConnect leaves only the input lockout voltage to protect the starter battery.
  • The alternator sees more than 30 A. Output current times output voltage, divided by efficiency and the lower input voltage, is what the starter side supplies, so the input cable, its fuse and the alternator's spare capacity are all budgeted above the nameplate.
  • VictronConnect does not show current. The Orion-Tr Smart range has no current sensor and no VE.Direct port; the non-isolated datasheet prints both as notes. A shunt on the house bank is how you see the amps.
  • Units can be paralleled, without limit per the datasheet, which is how installers get past 30 A without moving to a different product line.

What do owners and installers say about the Orion-Tr Smart 12/12-30?

  • "It gets hot and folds back." The recurring report is a unit that delivers its 30 A cold and settles to roughly 20–25 A once the case is hot in an enclosed compartment; a fan over the fins or relocating it into moving air restores the output. See this thread, this one and the T6 forum. Victron's answer in those threads is that the derating is by design and the fix is airflow.
  • Smart alternators stop it charging. Owners of Fiat Ducato, VW Transporter and Ford Transit vans describe charging that cuts out under "engine shutdown detected"; the fix agreed in this thread and on MotorhomeFun is the ignition or D+ feed to the remote connector, not disabling detection.
  • Fuse placement is asked and answered often. The isolated fuse placement thread and the fusing thread settle on a fuse at each battery, sized for the cable.
  • New builds are steered to the Orion XS. Installers and resellers now recommend the XS 12/12-50 where isolation is not required, for its efficiency, size and current readout; see this comparison and this Victron Community thread. The isolated Orion-Tr Smart remains the pick when the banks must not share a negative.

What belongs around the Orion-Tr Smart 12/12-30?

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Orion-Tr Smart 12/12-30 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Isolated 30A DC-DC charger from start to house battery. Engine-run detection from input voltage; Victron's manual calls for a 60A fuse on the input side.

Compatible systems
12 V
Rated output
30 A
Planning charge current
28 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

IN +

positive · input

60 A

IN −

negative · input

60 A

OUT +

positive · output

30 A

OUT −

negative · output

30 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Orion 30A.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.