Victron Orion-Tr 24/12-15 wiring diagram

Orion-Tr 24/12-15 non-isolated supply for 12V loads: 18–35V input, fixed 12.5V output and 15A continuous current. Both negatives are common; connect the negative supply first.

Nominal input
24 V
Nominal output
12 V
Rated output
15 A
Units

Wiring diagram

How the Orion 24/12-15 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron Orion-Tr 24/12-15 wiring example with 3 components: Source bank, Orion 24/12-15, Reference load. 4 cable connections. Crossings are not junctions.Source bank + to Orion 24/12-15 IN +: 1.5 mm² · 15 A fuse, 3 m one way. Orion 24/12-15 OUT + to Reference load +: 4 mm² · 15 A fuse, 3 m one way. Source bank − to Orion 24/12-15 IN −: 4 mm², 3 m one way. Orion 24/12-15 OUT − to Reference load −: 4 mm², 3 m one waySource bank + to Orion 24/12-15 IN +: 1.5 mm² · 15 A fuse, 3 m one wayOrion 24/12-15 OUT + to Reference load +: 4 mm² · 15 A fuse, 3 m one waySource bank − to Orion 24/12-15 IN −: 4 mm², 3 m one wayOrion 24/12-15 OUT − to Reference load −: 4 mm², 3 m one way24 V 200 Ah source bankSource bank++−−Victron Orion-Tr 24/12-15. 24 V source to 12 V nominal DC loads only; this non-Smart converter is not intended for battery charging. Verify the actual output before connecting loads. The canvas uses the declared 24 V input, 12.5 V output and 97% nominal efficiency to model conversion; this is a planning model, not an efficiency curve for every operating condition. Review generated wire and fuse values for each actual voltage, source fault current and conductor. Input and output share a common negative; the drawing's two return connections are electrically common.Orion 24/12-15IN +IN +IN −IN −OUT +OUT +OUT −OUT −12 V reference load. 10 A placeholder load at 12 V; replace with actual running and startup demand within the converter's voltage, current and power limits.Reference load++−−1.5 mm² · 15 A fuse4 mm² · 15 A fuse4 mm²4 mm²
Victron Orion-Tr 24/12-15 wiring example with 3 components: Source bank, Orion 24/12-15, Reference load. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Version 03 — 09/06/2017), checked 2026-10-01. Manufacturer documentation →

What is this 24/12-15?

The Orion-Tr 24/12-15 non-isolated converts a nominal 24 V supply to a fixed 12.5 V output for 12 V loads. The model specification table gives 18–35 V input, 15 A continuous output, and 20 A maximum output. The maximum figure is not the continuous design rating. This fixed-voltage supply has no documented battery-charge profile; do not use this walkthrough as a house-battery charging scheme.

It is distinct from the isolated adjustable Orion-Tr and from Bluetooth Orion-Tr Smart chargers. The original catalog photograph depicted a 12/12-9 isolated converter and was removed because it did not identify this model.

What do the four terminals mean?

IN + / IN − represent source positive and negative; OUT + / OUT − represent the regulated load supply. The two physical minus terminals are internally interconnected. There is no galvanic isolation between source and load, and no documented Smart charger setup or engine-detection menu.

Connect the negative supply first. The installation sheet specifically warns that a poor negative connection can cause output overvoltage. Use a sound common-return path sized for the load; do not assume the two negative symbols create isolated systems. The terminal capacity is 6 mm² / AWG 10. No terminal tightening torque is specified in these reviewed sources.

How should protection be selected?

Protect the source-side positive wiring near the supplying battery and provide suitable protection for downstream load branches. Select protection from the actual conductor, connected load, and installation conditions. The installation sheet's 5 A external fuse instruction applies only to the 24/12-5, not this 15 A unit. It does not provide a model-specific external fuse value for the 24/12-15, so that sibling's fuse must not be copied here.

Before connecting valuable loads, verify the 24 V source polarity, the common negative, and the 12.5 V output. Calculate voltage drop in both input and output conductors. Keep sustained demand within 15 A, accounting for starting surges and ambient temperature rather than treating 20 A as a normal operating target.

What are the installation limits?

Choose a cool, dry, ventilated location. IP43 protection applies with screw terminals facing downwards. The specified temperature range is −20 to +55°C, with 3% per °C derating above 40°C. Keep the converter and exposed connections away from spray and battery gases, and verify stable output under the intended load after installation.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Orion-Tr 24/12-15 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Orion-Tr 24/12-15 non-isolated supply for 12V loads: 18–35V input, fixed 12.5V output and 15A continuous current. Both negatives are common; connect the negative supply first.

Nominal input
24 V
Nominal output
12 V
Rated output
15 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

IN +

positive · input

20 A

IN −

negative · input

20 A

OUT +

positive · output

15 A

OUT −

negative · output

15 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.