Orion 24/12-70 (840W)

Victron Orion 24/12-70 wiring diagram

Older non-isolated 24-to-12 V, 70 A regulated converter. Factory output is 13.2 V, adjustable from 10 to 15 V with a small load connected. Shared negative; no automatic battery charge profile is documented.

Nominal input
24 V
Nominal output
12 V
Compatible systems
12 V / 24 V
Units

Wiring diagram

How the Orion 24/12-70 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron Orion 24/12-70 wiring example with 3 components: Source bank, Orion 24/12-70, Reference load. 4 cable connections. Crossings are not junctions.Source bank + to Orion 24/12-70 IN +: 6 mm² · 50 A fuse, 3 m one way. Orion 24/12-70 OUT + to Reference load +: 10 mm² · 40 A fuse, 3 m one way. Source bank − to Orion 24/12-70 IN −: 6 mm², 3 m one way. Orion 24/12-70 OUT − to Reference load −: 10 mm², 3 m one waySource bank + to Orion 24/12-70 IN +: 6 mm² · 50 A fuse, 3 m one wayOrion 24/12-70 OUT + to Reference load +: 10 mm² · 40 A fuse, 3 m one waySource bank − to Orion 24/12-70 IN −: 6 mm², 3 m one wayOrion 24/12-70 OUT − to Reference load −: 10 mm², 3 m one way24 V 200 Ah source bankSource bank++−−Victron Orion 24/12-70. 24 V source to 12 V nominal DC loads only; this non-Smart converter is not intended for battery charging. Verify the actual output before connecting loads. The canvas uses the declared 24 V input, 12 V output and 92% nominal efficiency to model conversion; this is a planning model, not an efficiency curve for every operating condition. Review generated wire and fuse values for each actual voltage, source fault current and conductor. Input and output share a common negative; the drawing's two return connections are electrically common.Orion 24/12-70IN +IN +IN −IN −OUT +OUT +OUT −OUT −12 V reference load. 30 A placeholder load at 12 V; replace with actual running and startup demand within the converter's voltage, current and power limits.Reference load++−−6 mm² · 50 A fuse10 mm² · 40 A fuse6 mm²10 mm²
Victron Orion 24/12-70 wiring example with 3 components: Source bank, Orion 24/12-70, Reference load. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

Cable sizes depend on the connected equipment, current and cable lengths. Add those details in Crimp to size each run.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Version 01 — 07 November 2012), checked 2026-10-01. Manufacturer documentation →

Which Orion does this cover?

This is the older Orion 24/12-70 non-isolated converter, covered by Victron's model-specific installation leaflet. It is a regulated 24 V to 12 V supply with a manually adjusted output. Do not substitute instructions for the newer 24/12-80 or for an Orion-Tr Smart charger merely because they have similar names.

The leaflet specifies 13.2 V factory output, adjustable from 10 to 15 V. It does not describe an automatic bulk/absorption/float charging algorithm. A connected battery therefore requires a separately reviewed charging application; the catalog's “charger” category is not evidence of that suitability.

How is it wired?

IN + receives the 24 V source positive and OUT + supplies the 12 V circuit. The symbol's IN − and OUT − represent the shared negative connection, not an isolation barrier. Victron instructs you to connect the negative cables to the Orion's negative terminal before the remaining cabling. A poor negative connection can cause excessive output voltage.

The green remote connector is omitted from the drawing. Replace its wire bridge with a low-current switch, or follow the leaflet's alternative switched 24 V connection. The switched control current is below 100 mA; that does not make the main supply a low-current circuit.

How should the output be set?

Connect a small load while adjusting the potentiometer. The no-load voltage can be slightly higher, so setting it with no load can produce a lower voltage once a load is attached. Turning counterclockwise lowers voltage; clockwise raises it. Measure at the converter and at the load after the adjustment.

Use the voltage required by the actual load. Avoid treating the full 10–15 V adjustment range as acceptable for every nominal 12 V device.

What is still installation-specific?

Mount in a cool, dry, ventilated location and secure the heavy power cables independently of the control connector. The leaflet does not state cable cross-sections, an external fuse amperage, or a power-terminal tightening torque. Those values need the actual hardware, cable run, source protection, and installation design; they should not be copied from a different Orion model.

The drawing also does not simulate output adjustment, the shared physical negative terminal, or remote switching. Verify those details against the installed unit before energizing it.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with Orion 24/12-70 (840W) connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Older non-isolated 24-to-12 V, 70 A regulated converter. Factory output is 13.2 V, adjustable from 10 to 15 V with a small load connected. Shared negative; no automatic battery charge profile is documented.

Nominal input
24 V
Nominal output
12 V
Compatible systems
12 V / 24 V
Rated output
70 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

IN +

positive · input

50 A

IN −

negative · input

50 A

OUT +

positive · output

85 A

OUT −

negative · output

85 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Wire sizes and fuse ratings apply to the connected example, not a fixed cable size for this component. Set your actual equipment, current, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Orion 24/12-70.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.