Engine 38HP — Volvo Penta D2-40 wiring diagram

Volvo Penta D2-40 family. The D2-40F manual specifies 12 V, a 2.0 kW starter and 115 A alternator. Modeled 180 A cranking and 360 A surge are estimates; match the engine suffix, panel and electrically isolated drive arrangement.

Continuous draw
180 A
Rated output
115 A
Surge current
360 A
Units

Wiring diagram

How the D2-40 38HP is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Engine 38HP — Volvo Penta D2-40 wiring example with 4 components: D2-40 38HP, Starter bank, 30 A DC/DC charger, House bank. 7 cable connections. Crossings are not junctions.D2-40 38HP Alt B+ to Starter bank +: 35 mm² · 150 A fuse, 3 m one way. D2-40 38HP Block GND to Starter bank −: 120 mm², 3 m one way. Starter bank + to D2-40 38HP Starter: 120 mm² · 250 A fuse, 3 m one way. Starter bank + to 30 A DC/DC charger IN +: 10 mm² · 50 A fuse, 3 m one way. Starter bank − to 30 A DC/DC charger IN −: 10 mm², 3 m one way. 30 A DC/DC charger OUT + to House bank +: 10 mm² · 40 A fuse, 3 m one way. 30 A DC/DC charger OUT − to House bank −: 10 mm², 3 m one wayD2-40 38HP Alt B+ to Starter bank +: 35 mm² · 150 A fuse, 3 m one wayD2-40 38HP Block GND to Starter bank −: 120 mm², 3 m one wayStarter bank + to D2-40 38HP Starter: 120 mm² · 250 A fuse, 3 m one wayStarter bank + to 30 A DC/DC charger IN +: 10 mm² · 50 A fuse, 3 m one wayStarter bank − to 30 A DC/DC charger IN −: 10 mm², 3 m one way30 A DC/DC charger OUT + to House bank +: 10 mm² · 40 A fuse, 3 m one way30 A DC/DC charger OUT − to House bank −: 10 mm², 3 m one wayEngine 38HP — Volvo Penta D2-40. The starter input and alternator output connect to the same starter bank. The DC/DC charger limits charging of the separate house bank. This is the main DC power arrangement only: retain the engine's original controls, harness, bonding and alternator regulation. Verify cranking capacity, alternator reserve and manufacturer protection requirements.D2-40 38HPStarterStarterAlt B+Block GNDBlock GND12 V 200 Ah placeholder starter bank. 200 Ah placeholder bank. The 394 A discharge and 115 A charging envelopes are example assumptions, not specifications inferred from capacity. Replace them with actual battery, cranking and alternator-regulation evidence. Protect each battery-fed positive branch as required by its circuit.Starter bank++−−12 V 30 A DC/DC charging allowance. 30 A output, 34 A input and 90% efficiency are explicit planning assumptions for a 12/12 V charger. Choose the actual charger, set its input limit to the alternator's available continuous reserve, and follow its ignition/enable, fuse and cable requirements.30 A DC/DC chargerIN +IN +IN −IN −OUT +OUT +OUT −OUT −12 V 200 Ah placeholder house bank. 200 Ah placeholder bank accepting 30 A in this example. Verify the actual battery/BMS limits and configure the charger's battery profile before use.House bank++−−120 mm²120 mm² · 250 A fuse10 mm²10 mm² · 40 A fuse10 mm²
Engine 38HP — Volvo Penta D2-40 wiring example with 4 components: D2-40 38HP, Starter bank, 30 A DC/DC charger, House bank. 7 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
120 mm² · 4/0 AWG
Example fuse
250 A
Cranking current
180 A
Voltage drop
1.3%

Sized against ABYC E-11. The cranking current is what the starter draws. ABYC E-11 doesn't require a fuse on a cranking-motor conductor, so the fuse shown is the usual cranking-rated (Class T) choice, sized to hold the crank without nuisance tripping — it isn't there to protect the wire. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 120 mm² (4/0 AWG) marine cable
  2. Terminations for 120 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 250 A cranking-rated (Class T) fuse at the battery
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Reviewed against manufacturer family documentation (rev. 7748803 French — October 2020), checked 2026-10-01. Exact variant details still require confirmation. Manufacturer documentation →

Engine and edition

The downloaded Volvo D1/D2 operator manual explicitly covers D2-40F. Its electrical table specifies 12 V, a 70 Ah starter battery, a 14 V/115 A alternator and approximately 2.0 kW starter output. The unsuffixed catalog entry does not establish whether a particular engine is B, F or another production revision; confirm the product and serial numbers before selecting harness parts.

What the terminals mean

`Starter` represents the high-current starter supply, `Alt B+` the alternator charging output, and `Block GND` the intended negative return on an earth-return installation. They are functional drawing ports, not three interchangeable physical studs. Trace any factory link between alternator B+ and the starter battery stud before changing it; do not duplicate or remove that link without accounting for the original harness.

Controls and protection

The engine management/control system operates the start, stop and alarm functions. The manual identifies a blade fuse that interrupts an overloaded engine-control supply; investigate the cause if instruments or starting cease, rather than bypassing it. Its rating must be checked on the fitted harness. The manual separates the engine supply from accessory supplies and illustrates how return wiring can defeat electrical isolation of the drive. Retain the original engine-control protection and alarm connections. Do not interpret a missing alarm or panel port in the drawing as permission to omit that equipment.

Checks and model limits

Use the documented engine stop control before opening the main battery switch; this edition requires a 30-second delay after switching off the control system so engine data can be stored. A battery switch must not interrupt the charging circuit while the alternator is running. Keep starter and return cables short and assess voltage at the starter during cranking. The catalog 180 A cranking and 360 A inrush are estimates, not guaranteed maxima from Volvo. The simplified block-ground symbol does not authorize bonding an insulated saildrive or transmission to battery negative.

Source: manufacturer document — shutdown printed pp. 38–39 (PDF 40–41), electrical maintenance pp. 67–72 (PDF 69–74), D2-40F identity p. 83 (PDF 85), electrical ratings p. 88 (PDF 90). Legacy copies hosted outside the manufacturer site are manufacturer-authored archive documents; the review date does not make them current installation instructions.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with D2-40 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Volvo Penta D2-40 family. The D2-40F manual specifies 12 V, a 2.0 kW starter and 115 A alternator. Modeled 180 A cranking and 360 A surge are estimates; match the engine suffix, panel and electrically isolated drive arrangement.

Continuous draw
180 A
Rated output
115 A
Surge current
360 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

Starter

positive · input

600 A

Alt B+

positive · output

200 A

Block GND

ground · bidi

600 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with D2-40 38HP.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.