Engine 20HP — Bukh DV20 wiring diagram

Bukh DV20 family with generation-dependent starter, alternator and panel equipment. The modeled 55 A charging output, 110 A cranking and 220 A surge are unverified planning defaults; read the installed labels and the matching ME/SME manual before sizing wiring.

Continuous draw
110 A
Rated output
55 A
Surge current
220 A
Units

Wiring diagram

How the DV20 20HP is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Engine 20HP — Bukh DV20 wiring example with 4 components: DV20 20HP, Starter bank, 25 A DC/DC charger, House bank. 7 cable connections. Crossings are not junctions.DV20 20HP Alt B+ to Starter bank +: 25 mm² · 70 A fuse, 3 m one way. DV20 20HP Block GND to Starter bank −: 120 mm², 3 m one way. Starter bank + to DV20 20HP Starter: 120 mm² · 250 A fuse, 3 m one way. Starter bank + to 25 A DC/DC charger IN +: 10 mm² · 35 A fuse, 3 m one way. Starter bank − to 25 A DC/DC charger IN −: 10 mm², 3 m one way. 25 A DC/DC charger OUT + to House bank +: 10 mm² · 35 A fuse, 3 m one way. 25 A DC/DC charger OUT − to House bank −: 10 mm², 3 m one wayDV20 20HP Alt B+ to Starter bank +: 25 mm² · 70 A fuse, 3 m one wayDV20 20HP Block GND to Starter bank −: 120 mm², 3 m one wayStarter bank + to DV20 20HP Starter: 120 mm² · 250 A fuse, 3 m one wayStarter bank + to 25 A DC/DC charger IN +: 10 mm² · 35 A fuse, 3 m one wayStarter bank − to 25 A DC/DC charger IN −: 10 mm², 3 m one way25 A DC/DC charger OUT + to House bank +: 10 mm² · 35 A fuse, 3 m one way25 A DC/DC charger OUT − to House bank −: 10 mm², 3 m one wayEngine 20HP — Bukh DV20. The starter input and alternator output connect to the same starter bank. The DC/DC charger limits charging of the separate house bank. This is the main DC power arrangement only: retain the engine's original controls, harness, bonding and alternator regulation. Verify cranking capacity, alternator reserve and manufacturer protection requirements.DV20 20HPStarterStarterAlt B+Block GNDBlock GND12 V 200 Ah placeholder starter bank. 200 Ah placeholder bank. The 248 A discharge and 100 A charging envelopes are example assumptions, not specifications inferred from capacity. Replace them with actual battery, cranking and alternator-regulation evidence. Protect each battery-fed positive branch as required by its circuit.Starter bank++−−12 V 25 A DC/DC charging allowance. 25 A output, 28 A input and 90% efficiency are explicit planning assumptions for a 12/12 V charger. Choose the actual charger, set its input limit to the alternator's available continuous reserve, and follow its ignition/enable, fuse and cable requirements.25 A DC/DC chargerIN +IN +IN −IN −OUT +OUT +OUT −OUT −12 V 200 Ah placeholder house bank. 200 Ah placeholder bank accepting 25 A in this example. Verify the actual battery/BMS limits and configure the charger's battery profile before use.House bank++−−120 mm²120 mm² · 250 A fuse10 mm²10 mm² · 35 A fuse10 mm²
Engine 20HP — Bukh DV20 wiring example with 4 components: DV20 20HP, Starter bank, 25 A DC/DC charger, House bank. 7 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
120 mm² · 4/0 AWG
Example fuse
250 A
Cranking current
110 A
Voltage drop
0.8%

Sized against ABYC E-11. The cranking current is what the starter draws. ABYC E-11 doesn't require a fuse on a cranking-motor conductor, so the fuse shown is the usual cranking-rated (Class T) choice, sized to hold the crank without nuisance tripping — it isn't there to protect the wire. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 120 mm² (4/0 AWG) marine cable
  2. Terminations for 120 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 250 A cranking-rated (Class T) fuse at the battery
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Reviewed against manufacturer family documentation (rev. Undated manufacturer document; printed revision not established), checked 2026-10-01. Exact variant details still require confirmation. Manufacturer documentation →

Engine and edition

BUKH’s archived handbook covers DV10 and DV20 M/ME/SME versions. The electrical discussion applies to ME equipment. It does not support the previous claim that every DV20 has a 1.0 kW Bosch starter and 55 A Bosch alternator: its specification table lists alternative starter makes, 2 hp starting power and a Paris-Rhône alternator rated 700 W.

What the terminals mean

`Starter` represents the high-current starter supply, `Alt B+` the alternator charging output, and `Block GND` the intended negative return on an earth-return installation. They are functional drawing ports, not three interchangeable physical studs. Trace any factory link between alternator B+ and the starter battery stud before changing it; do not duplicate or remove that link without accounting for the original harness.

Controls and protection

Figure 20 identifies the battery switch, starter, alternator B+/61+/D− connections, stop magnet, engine warning senders and panel fuse assembly. These are separate power, excitation and control functions. Match the fitted panel and harness before rewiring. The catalog exposes only the full-current starter feed, charging output and engine return; it omits the stop-magnet and warning circuits.

Checks and model limits

The handbook’s prose also mentions approximately 30 A maximum charging current, which does not cleanly reconcile with its 700 W table. Accordingly, neither value is silently converted into a new universal alternator rating. The catalog 55 A output, 110 A cranking and 220 A surge remain unverified planning defaults that must be replaced with fitted-equipment information. Do not use a battery-disconnect switch as the normal stop control, or disconnect a running alternator from its battery. Control-fuse and cable values must be confirmed on the installed ME/SME arrangement.

Source: manufacturer document — electrical diagram printed p. 17 (PDF 19), electrical-system discussion p. 19 (PDF 21), electrical ratings p. 31 (PDF 33). Legacy copies hosted outside the manufacturer site are manufacturer-authored archive documents; the review date does not make them current installation instructions.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with DV20 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Bukh DV20 family with generation-dependent starter, alternator and panel equipment. The modeled 55 A charging output, 110 A cranking and 220 A surge are unverified planning defaults; read the installed labels and the matching ME/SME manual before sizing wiring.

Continuous draw
110 A
Rated output
55 A
Surge current
220 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

Starter

positive · input

400 A

Alt B+

positive · output

200 A

Block GND

ground · bidi

400 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works