MultiPlus-II 48/5000/70-50

Victron MultiPlus-II 48/5000 wiring diagram

230 V MultiPlus-II 48/5000/70-50: 5000 VA / 4000 W inverter, 70 A charger and 50 A feed-through. PowerAssist supplements the AC source. Battery/BMS controls, grounding and output protection need separate configuration.

Compatible systems
48 V
Rated power
4,000 W
Continuous draw
100 A
Units

Wiring diagram

How the MultiPlus-II 48/5000 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Victron MultiPlus-II 48/5000 wiring example with 3 components: House bank, Battery disconnect, MultiPlus-II 48/5000. 3 cable connections. Crossings are not junctions.Battery disconnect B to MultiPlus-II 48/5000 DC +: 70 mm² · 200 A fuse, 3 m one way. House bank − to MultiPlus-II 48/5000 DC −: 70 mm², 3 m one way. House bank + to Battery disconnect A: 70 mm² · 200 A fuse, 30 cm one wayBattery disconnect B to MultiPlus-II 48/5000 DC +: 70 mm² · 200 A fuse, 3 m one wayHouse bank − to MultiPlus-II 48/5000 DC −: 70 mm², 3 m one wayHouse bank + to Battery disconnect A: 70 mm² · 200 A fuse, 30 cm one way48 V 200 Ah house bankHouse bank++−−Main Battery SwitchBattery disconnectABVictron MultiPlus-II 48/5000. DC-only example for the 48/5000/70-50: 200 A battery protection and 70 mm² per polarity follow the manual's 0–5 m table. The 3.048 m main leads plus 0.3 m positive disconnect link stay in that range. Verify the actual fuse/holder, battery capability, 90°C copper installation conditions, AC wiring and protective earth separately.MultiPlus-II 48/5000DC +DC +DC −DC −70 mm² · 200 A fuse70 mm²70 mm² · 200 A fuse
Victron MultiPlus-II 48/5000 wiring example with 3 components: House bank, Battery disconnect, MultiPlus-II 48/5000. 3 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.

DC-only example for the 48/5000/70-50: 200 A battery protection and 70 mm² per polarity follow the manual's 0–5 m table. The 3.048 m main leads plus 0.3 m positive disconnect link stay in that range. Verify the actual fuse/holder, battery capability, 90°C copper installation conditions, AC wiring and protective earth separately. Manufacturer installation manual

Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

48 V system

Wire
70 mm² · 2/0 AWG
Example fuse
200 A
Design current
100 A
Voltage drop
0.3%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

DC-only example for the 48/5000/70-50: 200 A battery protection and 70 mm² per polarity follow the manual's 0–5 m table. The 3.048 m main leads plus 0.3 m positive disconnect link stay in that range. Verify the actual fuse/holder, battery capability, 90°C copper installation conditions, AC wiring and protective earth separately. Manufacturer installation manual

Supporting parts

  1. 6.1 m total of 70 mm² (2/0 AWG) marine cable
  2. Terminations for 70 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 200 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. Rev 14 — 07/2026), checked 2026-10-01. Manufacturer documentation →

Which 48/5000 does this cover?

This note uses the 230 V MultiPlus-II 48/5000/70-50 manual. Confirm 230 V on the nameplate before applying its AC instructions. The model provides 5000 VA / 4000 W continuous inverter output at 25°C, 70 A battery charging, and 50 A maximum AC feed-through. Continuous output falls to 3700 W at 40°C. It belongs on a nominal 48 V battery system.

Which physical connections are missing?

AC IN L / N are the incoming supply and AC OUT L / N represent backed-up AC-out-1. DC + / DC − connect the battery and carry both charge and discharge current. The symbol omits protective earth, chassis grounding, AC-out-2, VE.Bus, remote control, sensing, and optional external current sensing.

AC-out-2 is a separate, mains-only output, with a 32 A rating in this model's specification table. It disconnects during inverter operation and reconnects about two minutes after external AC returns. It is suitable only for loads intended to stop during battery operation.

What battery cable and fuse does Victron specify?

The battery table, printed page 14 lists a 200 A DC fuse, 70 mm² per polarity for 0–5 m, or 120 mm² for 5–10 m. The table assumes 90°C copper and excludes closed-conduit installation. Maximum M8 battery-stud torque is 12 N·m. Its 200–800 Ah recommended bank range does not prove that a particular battery or BMS can deliver inverter surge current.

Keep the battery path short and secure the cables. Follow the installed battery's limits for charging, discharge, fault protection, and any contactor or precharge requirements.

How are AC and battery settings coordinated?

Printed page 15 requires an AC input fuse or breaker rated 50 A or less, reduced for the actual supply. Configure the input-current limit accordingly. PowerAssist can supplement incoming AC from the battery, so main-output protection and wiring need their own calculation; the 50 A input rating is not an output design by itself.

Configure the charging profile and current to match the specific battery. A compatible lithium system also needs the correct BMS communication/control arrangement; a brand name alone does not establish compatibility. AC-coupled solar, parallel operation, and grid-connected ESS require their own system configuration beyond the canvas.

What grounding and mounting details matter?

Maintain protective-earth continuity. The internal relay bonds output neutral to chassis during inverter operation and opens before connecting external AC. Verify residual-current protection in both operating modes. Mount in a dry, ventilated location with the manual's clearances, accessible connections, and a suitable supporting surface.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with MultiPlus-II 48/5000/70-50 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

230 V MultiPlus-II 48/5000/70-50: 5000 VA / 4000 W inverter, 70 A charger and 50 A feed-through. PowerAssist supplements the AC source. Battery/BMS controls, grounding and output protection need separate configuration.

Compatible systems
48 V
Rated power
4,000 W
Continuous draw
100 A
Rated output
70 A
Surge current
200 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

AC IN L

neutral · input

50 A

AC IN N

neutral · input

50 A

DC +

positive · input

200 A

DC −

negative · input

200 A

AC OUT L

neutral · output

25 A

AC OUT N

neutral · output

25 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with MultiPlus-II 48/5000.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.