Pictured universal-input Smart IP43 12/50 (3): three isolated positive outputs share 50A total, one charge profile and a common negative. Input 85–250 VAC; dry, ventilated mounting with protective earth.
- Rated output
- 50 A
Wiring diagram
How the Phoenix 50-3 is wired.
Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.
Cable sizing for this example
Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.
3 m one way
12 V system
- Wire
- 16 mm² · 6 AWG
- Example fuse
- 70 A
- Design current
- 50 A
- Voltage drop
- 2.8%
Sized against ABYC E-11. The design current is the unit's rated output. The length is one way; voltage drop includes an equal-length return.
Run-length and manufacturer assumptions
The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.
Supporting parts
- 6.1 m total of 16 mm² (6 AWG) marine cable
- Terminations for 16 mm² cable, matched to the equipment's screw terminals, leads or studs
- 70 A fuse and holder on the positive run
- Heat-shrink, strain relief and terminal boots sized to the cable
Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.
Installation notes
Before you install.
Open a question for model-specific guidance and sources.
Verified against the manufacturer's documentation (rev. Rev 10 — 09/2026), checked 2026-10-01. Manufacturer documentation →
Which Smart IP43 is covered?
These notes cover the Smart IP43 12/50 (3), 120–240 V version visible in the catalog photograph. It supplies up to 50 A total to nominal 12 V batteries. The current manual specifies 85–250 VAC, startup from 90 VAC and full power from 100 VAC. Older 230 V-only Phoenix units need their matching instructions; the family name alone does not make their input range or auxiliary rating identical.
How do the outputs map?
BATT 1/2/3 + map to three FET-isolated positives. The charger has one common negative; the three negative symbols are logical connections to a common bus. Each battery positive needs its own protection near that battery. All outputs share the total current and one charging algorithm, so their batteries must be compatible with the same voltage profile.
AC L / N / earth describe the IEC mains inlet and protective-earth connection. The symbol omits remote H/L, programmable relay, and VE.Direct. Use the correct mains cord with its retainer and an earthed outlet. The remote connector can receive a compatible BMS charge-permission control; it does not carry charging current.
What cable and protection are specified?
The printed page 19 table recommends 16 mm² through 3 m one way; longer listed runs are not recommended with the supported terminal size. These values assume at least 90°C insulation, open unbundled routing at 30°C, equal positive/negative lengths, and a 3% voltage-drop limit. They do not approve the same cable in every conduit or engine space.
Main DC terminals accept up to 16 mm² and tighten to 2.4 N·m. Fit suitable protection close to each battery positive. This manual's wiring diagrams require fuses/breakers but do not give a universal model-specific fuse amperage; select the rating with the installed conductor and battery fault current rather than borrowing another charger family's table.
What must be set before charging?
Select battery chemistry, charge voltage/current, and any required BMS control before use. Low mode limits this model to 25 A. Normal mode is 14.4 V absorption, 13.8 V float and 13.2 V storage; lithium uses its own preset without lead-acid temperature compensation. Configure all banks for one compatible charging profile. Remote control and the programmable relay have distinct functions; a relay signal is not a substitute for wiring the charge-disable input correctly.
How is the installation checked?
Mount vertically, terminals down, with 100 mm ventilation space above and below, on a nonflammable surface. Use a protected, dry location away from battery gases. Verify each bank's polarity and charging voltage, then test the configured current limit and any BMS stop command. The specification table rates full current through 40°C; heat and connected loads reduce charging headroom.
Fit check
Connect it to the rest of your system.
Describe your setup to draft a system with Phoenix Smart IP43 12/50-3 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.
The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.
Enable JavaScript to describe your system.
Technical reference
Specifications and terminal map.
Check the model, ratings and connection points against your own unit before choosing installation hardware.
Catalog specification
Pictured universal-input Smart IP43 12/50 (3): three isolated positive outputs share 50A total, one charge profile and a common negative. Input 85–250 VAC; dry, ventilated mounting with protective earth.
- Rated output
- 50 A
- Planning charge current
- 47 A
Terminal map
Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.
AC L
neutral · input
AC N
neutral · input
AC ⏚
ground · bidi
BATT 1 +
positive · output
BATT 1 −
negative · output
BATT 2 +
positive · output
BATT 2 −
negative · output
BATT 3 +
positive · output
BATT 3 −
negative · output
Sources and sizing method
Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.
Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.