Load

Dometic CRX-50 Fridge wiring diagram

Built-in CRX50 compressor fridge with removable freezer compartment. Rated 5A at 12V or 2.6A at 24V; compressor duty varies with temperature and ventilation. Dometic specifies a 15A protected DC supply at 12V, or 7.5A at 24V, and an open rear ventilation path.

Compatible systems
12 V / 24 V
Continuous draw
5 A
Units

Wiring diagram

How the Fridge CRX-50 is wired.

Open this example in Crimp to use your own parts and cable lengths. Review the assumptions and installation notes as you adapt the circuit.

Dometic CRX-50 Fridge wiring example with 3 components: House bank, Fused DC distribution, Fridge CRX-50. 4 cable connections. Crossings are not junctions.Fused DC distribution 1 to Fridge CRX-50 +: 4 mm² · 15 A fuse, 3 m one way. Fused DC distribution 1 to Fridge CRX-50 −: 4 mm², 3 m one way. House bank + to Fused DC distribution IN +: 4 mm² · 15 A fuse, 30 cm one way. House bank − to Fused DC distribution IN −: 4 mm², 30 cm one wayFused DC distribution 1 to Fridge CRX-50 +: 4 mm² · 15 A fuse, 3 m one wayFused DC distribution 1 to Fridge CRX-50 −: 4 mm², 3 m one wayHouse bank + to Fused DC distribution IN +: 4 mm² · 15 A fuse, 30 cm one wayHouse bank − to Fused DC distribution IN −: 4 mm², 30 cm one way12 V 200 Ah house bankHouse bank++−−Blue Sea 5025 ST Blade Fuse BlockFused DC distributionIN +IN +IN −IN −1111Dometic CRX-50 FridgeFridge CRX-50++−−4 mm² · 15 A fuse4 mm²4 mm² · 15 A fuse4 mm²
Dometic CRX-50 Fridge wiring example with 3 components: House bank, Fused DC distribution, Fridge CRX-50. 4 cable connections. Crossings are not junctions.Red = positive · dark = return · dashed = signal. Wire sizes and fuse ratings are example values; use the equipment instructions and actual installation lengths.
Edit this wiring example

Cable sizing for this example

Use the diagram as a starting point for your installation. Replace the example equipment and cable lengths with your own, and check the connections against your exact model's instructions.

3 m one way

12 V system

Wire
4 mm² · 11 AWG
Example fuse
15 A
Design current
5 A
Voltage drop
1.1%

Sized against ABYC E-11. The design current is the part's continuous draw. The length is one way; voltage drop includes an equal-length return.

Run-length and manufacturer assumptions

The editable example uses 3.048 m (10 ft) runs unless a shorter run is stated. Metric overviews round these to 3 m. Adapt the parts and lengths to your installation before choosing cable and protection.

Supporting parts

  1. 6.1 m total of 4 mm² (11 AWG) marine cable
  2. Terminations for 4 mm² cable, matched to the equipment's screw terminals, leads or studs
  3. 15 A fuse and holder on the positive run
  4. Heat-shrink, strain relief and terminal boots sized to the cable

Check stud sizes, fuse type, run length and how warm the space gets against the gear you actually have before you order.

Installation notes

Before you install.

Open a question for model-specific guidance and sources.

Verified against the manufacturer's documentation (rev. 4445103148 — 2021-06-01), checked 2026-09-30. Manufacturer documentation →

Which CRX-50 is covered?

This component represents the 12/24 V DC supply of the CoolMatic CRX50 compressor refrigerator. Dometic's CRX installation and operating manual, page 39 distinguishes DC and ACDC versions and rates the CRX50 at 5.0 A on 12 V or 2.6 A on 24 V. ACDC models have additional mains equipment; the DC-only model needs the specified external rectifier for mains operation. Confirm the full model and supply marking on the appliance label.

The compressor cycles with temperature, ventilation and use. The daily-hours setting is an energy-budget assumption, not a promise that the fridge draws 5 A continuously or uses the same amp-hours every day. Measure consumption in the installed cabinet when battery endurance matters.

How should the DC supply be wired?

The DC connection instructions, pages 24–26 specify red to battery positive and black to negative, with a 15 A protected supply at 12 V or 7.5 A at 24 V. These protection ratings differ from the running current. Use the manual's separate 12 V and 24 V cable-length diagrams when choosing conductors; keep the route short and avoid unnecessary connectors or switches that add voltage drop. Check cable ampacity as well as the appliance's voltage-drop requirement.

On a 12 V supply, the internal monitor cuts out at 10.4 V and restarts at 11.7 V. The 24 V thresholds are 22.8 V and 24.2 V. These are appliance operating thresholds, not a recommended discharge target for your battery chemistry. If the compressor will not start, check voltage at the fridge terminals during a start attempt, together with connections and cable size; a satisfactory battery-terminal reading can conceal a poor feed.

What does the cabinet installation need?

The installation diagrams, pages 17–19 show cooler air entering below and heated air escaping above, with approximately 50 mm rear clearance. Keep the condenser airflow path open. The unit must be secured, and its drain kept clear.

For troubleshooting, the CRX50 table on page 36 identifies one repeating LED flash as a supply-voltage fault and five as electronics overheating. Check those causes before assuming the compressor has failed.

Fit check

Connect it to the rest of your system.

Describe your setup to draft a system with CRX-50 connected. Review the selected parts and cable lengths, then edit the diagram in Crimp.

The model only picks parts and draws the connections. Every wire size and fuse rating still comes from Crimp's own sizing, never from the model.

Enable JavaScript to describe your system.

Technical reference

Specifications and terminal map.

Check the model, ratings and connection points against your own unit before choosing installation hardware.

Catalog specification

Built-in CRX50 compressor fridge with removable freezer compartment. Rated 5A at 12V or 2.6A at 24V; compressor duty varies with temperature and ventilation. Dometic specifies a 15A protected DC supply at 12V, or 7.5A at 24V, and an open rear ventilation path.

Compatible systems
12 V / 24 V
Continuous draw
5 A

Terminal map

Catalog connection points, current direction and planning limits. Check the manufacturer's pinout and connector ratings before installation.

+

positive · input

5 A

−

negative · input

5 A
Sources and sizing method

Equipment specifications. Model details, ratings and terminal roles come from the catalog. Check your unit’s label and current manufacturer documentation for its exact revision.

Example sizing. Sized against ABYC E-11. Boats built to UK or EU rules answer to ISO 13297 — check these figures against it before you build. Results use the example current and run length shown above. Set your actual equipment, lengths and installation conditions in Crimp before choosing hardware.

Read how the sizing works

Next step

Plan your installation with Fridge CRX-50.

Open this example as a new project, or add this component to your existing diagram. Use your equipment and cable lengths to review the sizing.

Start drawing, sizing and checking without an account. Your drawing saves in this browser. See Pricing for the equipment allowance and the one-time export offer available to you.